Next revision Both sides next revision
dictionary:unitcontrol:turnon [2016/03/14 19:12]
127.0.0.1 external edit
dictionary:unitcontrol:turnon [2019/06/09 13:38]
James Sentman [Color Support] fixed for new plugin color handling
Line 9: Line 9:
  
 ===optional parameters:​=== ===optional parameters:​===
-**in** (integernumber of seconds)\\ +  * **in** (integer: seconds) If specified an event is created to apply your new settings after this number of seconds. 
-**at** (date, instead ​of in” you can pass a specific date, see below for examples)\\ +  ​* ​**at** (date) Instead ​of the **in** param you may specify ​a specific date at which to create the event. 
-\\ +  ​* ​**for** (integerseconds) ​returns the unit to it’s current state this many seconds after any **in** or **at** event has run. 
-**for** (integer, number of seconds)\\ +  ​* ​**until** (date) similar to **for** but pass the specific date at which you wish the unit to return to it’s current state 
-**until** (date, instead of “for” you can pass specific date, see below for examples)\\ +  * **rate** (number: secondsThe number of seconds you wish the transition to take. You may specify a fractional seconds value such as 0.2 or 7.5. Not all devices support a rate param. 
-\\ +  ​* ​**with no script** ​Stops the on or off script from running. 
-**with no script** ​(stops ​the ON or OFF script from running)\\ +  ​* ​**with no transmit** ​Updates ​the database but doesn'​t actually send the command.
-**with no transmit** ​(updates ​the database but doesn'​t actually send the command)\\ +
-**rate** (integer, many devices support sending a ramp rate along with the command to control how fast the new level is reached)\\+
  
 ===Color Support=== ===Color Support===
  
-Many color capable bulbs are now available for ZWave and ZigBee via the [[supported_hardware:​hue|Phillips Hue]] hub. XTension can also create an “RGB Pseudo” that groups any 3 other units as the red, green and blue channels of a single fixture. Even if your device is not directly supported as an individual color lamp the channels are usually available separately. This is normally the case with ZWave 3 channel controllers. There are several optional parameters to this command for setting color. Some are specific to the hue bulbs, others will work for any color capable ​device.+Additional optional params ​are available for color capable ​devices:
  
-**rgb color** (textstandard HTML color string ​with each 2 characters being 00 to FF a hex representation of the level of that color in the mix. All color devices support ​the rgb color command. This is the normal way to set the color of a bulb. “FF0000” would be full red, “0000FF” would be full blue.)\\ +  * **rgb color** (text:html color “RRGGBB"​) accepts ​a string the same as an html color definition but without ​the “#” at the front. “FF0000” would be full red, “00FF00” would be full green and “0000FF” would be full blue.  
-**hue/​saturation** (integer, if using a Phillips Hue bulb you can set the color by passing the hue and saturationIf using this you must pass both the hue and saturation values.)\\ +  * **color temperature** (integer) The Mired color temperature ​you wish the bulb to displayThe range of available values is dependent on the individual device but would be in the range of 2000 to 50000 with 2700 being a warm white, 3500 being a “bright” or halogen white and 5000 to 6000 being a “daylight” color. Not all devices can display a color temperature
-**xvalue/​yvalue** (number, another method of sending color to a Phillips Hue bulb. If using this you must pass both the x and y coordinate values.)\\ +  * **color preset** (integer: 1-8) go to a color preset by index that you have already saved for the unit in XTension
-**color temperature** (integer, currently supported only for Phillips Hue bulbs this number corresponds ​to the color temperatureFor the hue bulbs this is not the actual color temperature in kelvin, but a number ​from 153 to 500 with larger numbers being warmerAs other bulbs become more commonly available that support changes in color temperature support will be added for those.)\\ +  * **hue/​saturation** (numbers) An alternative way to specify ​the color for a deviceYou must specify both the **hue** and **saturation** params to use this. The value is taken from the current brightness level of the device
-**color preset** (number, 1-8, all color capable devices can have 8 colors or color temperatures set as presets. You can recall one by passing ​the color preset number to this parameter.)+  * **xvalue/​yvalue** (numbers) Another alternative way to specify the color for a device. You must specify both the **xvalue** and **yvalue** the z value or brightness is taken from the current brightness level of the device.
  
 ===Color Handling=== ===Color Handling===
dictionary/unitcontrol/turnon.txt · Last modified: 2019/08/07 13:40 by James Sentman